6,462 research outputs found

    The VELO High Voltage System Control Software

    Get PDF
    This note describes the VELO high voltage control software. The implementation of its structure as a PVSS Finite State Machine is emphasized. The main error conditions that may occur during operation is also discussed. The VELO HV software conforms to the specification of the VELO

    First results from an aging test of a prototype RPC for the LHCb Muon System

    Get PDF
    Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm2^2, corresponding to about 4 years of LHCb running at the highest background rate. The performance of the chamber has been studied under several photon flux values exploiting a muon beam. A degradation of the rate capability above 1 kHz/cm2^2 is observed, which can be correlated to a sizeable increase of resistivity of the chamber plates. An increase of the chamber dark current is also observed. The chamber performance is found to fulfill the LHCb operation requirements.Comment: 6 pages, 9 figures, presented at the International Workshop on Aging Phenomena in Gaseous Detectors'', DESY-Hamburg (Germany), October 200

    Preliminary results of an aging test of RPC chambers for the LHCb Muon System

    Get PDF
    The preliminary results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge density of 0.42 C/cm^2, corresponding to about 4 years of LHCb running at the highest background rate. We observe a rise in the dark current and noise measured with source off. The current drawn with source on steadily decreased, possibly indicating an increase of resistivity of the chamber plates. The performance of the chamber, studied with a muon beam under several photon flux values, is found to still fulfill the LHCb operation requirements.Comment: 4 pages, 6 figures, presented at RPC2001, VIth Workshop on Resistive Plate Chambers and Related Detectors, November 26-27 2001, Coimbra, Portuga

    Ferromagnetism and ferroelectricity in epitaxial BiMnO3 ultra-thin films

    Get PDF
    We studied the ferroelectric and ferromagnetic properties of compressive strained and unstrained BiMnO3 thin films grown by rf-magnetron sputtering. BiMnO3 samples exhibit a two-dimensional cube-on-cube growth mode and a pseudo-cubic structure up to a thickness of 15 nm and of 25 nm when deposited on (001) SrTiO3 and (110) DyScO3, respectively. Above these thicknesses, we observe a switching to a three-dimensional island growth mode and a simultaneous structural change to a (00l) oriented monoclinic unit cell. While ferromagnetism is observed below a T-C approximate to 100K for all samples, signatures of room temperature ferroelectricity were found only in the pseudo-cubic ultra-thin films, indicating a correlation between electronic and structural orders

    New results from an extensive aging test on bakelite Resistive Plate Chambers

    Get PDF
    We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOhm to more than 250 MOhm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm2 to less than 0.15 kHz/cm2 is also found.Comment: 6 pages, 7 figures, presented at Siena 2002, 8th Topical Seminar on Innovative Particle and Radiation Detectors 21-24 October 2002, Siena, Ital

    The Transmissibility of Highly Pathogenic Avian Influenza in Commercial Poultry in Industrialised Countries

    Get PDF
    BACKGROUND: With the increased occurrence of outbreaks of H5N1 worldwide there is concern that the virus could enter commercial poultry farms with severe economic consequences. METHODOLOGY/PRINCIPAL FINDINGS: We analyse data from four recent outbreaks of highly pathogenic avian influenza (HPAI) in commercial poultry to estimate the farm-to-farm reproductive number for HPAI. The reproductive number is a key measure of the transmissibility of HPAI at the farm level because it can be used to evaluate the effectiveness of the control measures. In these outbreaks the mean farm-to-farm reproductive number prior to controls ranged from 1.1 to 2.4, with the maximum farm-based reproductive number in the range 2.2 to 3.2. Enhanced bio-security, movement restrictions and prompt isolation of the infected farms in all four outbreaks substantially reduced the reproductive number, but it remained close to the threshold value 1 necessary to ensure the disease will be eradicated. CONCLUSIONS/SIGNIFICANCE: Our results show that depending on the particular situation in which an outbreak of avian influenza occurs, current controls might not be enough to eradicate the disease, and therefore a close monitoring of the outbreak is required. The method we used for estimating the reproductive number is straightforward to implement and can be used in real-time. It therefore can be a useful tool to inform policy decisions

    A Laser Based Instrument for MWPC Wire Tension Measurement

    Get PDF
    A fast and simple method for the measurement of the mechanical tension of wires of Multi Wires Proportional Chambers (MWPCs) is described. The system is based on commercial components and does not require any electrical connection to the wires or electric or magnetic field. It has been developed for the quality control of MWPCs of the Muon Detector of the LHCb experiment in construction at CERN. The system allows a measurement of the wire tension with a precision better than 0.5% within 3-4 seconds per wir

    Performance of the LHCb muon system

    Full text link
    The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirementsComment: JINST_015P_1112 201

    Leading order analysis of neutrino induced dimuon events in the CHORUS experiment

    Get PDF
    We present a leading order QCD analysis of a sample of neutrino induced charged-current events with two muons in the final state originating in the lead-scintillating fibre calorimeter of the CHORUS detector. The results are based on a sample of 8910 neutrino and 430 antineutrino induced opposite-sign dimuon events collected during the exposure of the detector to the CERN Wide Band Neutrino Beam between 1995 and 1998. % with Eμ1,Eμ2>5E_{\mu 1},E_{\mu 2} > 5 GeV and Q2>3Q^2 > 3 GeV2^2 collected %between 1995 and 1998. The analysis yields a value of the charm quark mass of \mc = (1.26\pm 0.16 \pm 0.09) \GeVcc and a value of the ratio of the strange to non-strange sea in the nucleon of κ=0.33±0.05±0.05\kappa = 0.33 \pm 0.05 \pm 0.05, improving the results obtained in similar analyses by previous experiments.Comment: Submitted to Nuclear Physics
    • …
    corecore